Original Samsung INR18650 26JM Rechargeable Li Ion Battery KC UN38.3 IEC62133 Two Year Guarantee
Scope
This product specification has been prepared to specify the rechargeable lithium-ion cell
('cell') to be supplied to the customer by Samsung SDI Co., Ltd.
2. Description and Model
2.1 Description Cell (lithium-ion rechargeable cell)
2.2 Model ICR18650-26J1
3. Nominal Specifications
Item
Specification
3.1 Nominal Capacity
2600mAh (0.2C, 2.75V discharge)
3.2 Minimum Capacity
2550mAh(0.2C, 2.75V discharge)
3.3 Charging Voltage
4.2 ±0.05 V
3.4 Nominal Voltage
3.63V
3.5 Charging Method
CC-CV
(constant voltage with limited current)
3.6 Charging Current Standard charge:
1300
mA
Rapid charge : 2600
mA
3.7 Charging Time
Standard charge : 3hours
Rapid charge : 2.5hours
3.8 Max. Charge Current
2600mA(ambient temperature 25℃)
3.9 Max. Discharge Current
5200mA(ambient temperature 25℃)
3.10 Discharge Cut-off Voltage
2.75V
3.11 Cell Weight
45.0g max
3.12 Cell Dimension
Height :
65.00mm max
Diameter : 18.40mm max
3.13 Operating Temperature Charge : 0 to 45℃
Discharge: -20 to 60℃
3.14 Storage Temperature 1 year
: -20~25℃(1*)
3 months : -20~45℃(1*)
1 month : -20~60℃(1*)
5. Appearance
There shall be no such defects as scratch, rust, discoloration, leakage which
may adversely affect commercial value of the cell.
6. Standard Test Conditions
6.1 Environmental Conditions
Unless otherwise specified, all tests stated in this specification are
conducted at temperature 25±5℃ and humidity 65±20%.
6.2 Measuring Equipment
(1) Ammeter and Voltmeter
The ammeter and voltmeter should have an accuracy of
the grade 0.5 or higher.
(2) Slide caliper
The slide caliper should have 0.01 mm scale.
(3) Impedance meter
The impedance meter with AC 1kHz should be used.
7. Characteristics
7.1 Standard Charge
This "Standard Charge" means charging the cell with charge current
1300mA and constant voltage 4.2V at 25℃ for 3hours.
7.2 Standard Discharge Capacity
The standard discharge capacity is the initial discharge capacity of the cell, which is
measured with discharge current of 520mA with 2.75V cut-off at 25℃ within 1hour
after the standard charge.
Standard Discharge Capacity ≥ 2550mAh
7.3 Initial internal impedance
Initial internal impedance measured at AC 1kHz after rated charge.
Initial internal impedance ≤ 100mΩ
7.4 Temperature Dependence of Discharge Capacity
Capacity comparison at each temperature, measured with discharge
constant current 520mA and 2.75V cut-off after the standard charge is
as follows.
Note: If charge temperature and discharge temperature is not the same,
the interval for temperature change is 3 hours.
■ others
Don't fold the battery cased with laminated film such as pouch and Polymer.
Don't store the battery in a pocket or a bag together with metallic objects such as keys, necklaces,
hairpins, coins, or screws.
Don't short circuit (+) and (-) terminals with metallic object intentionally.
Don't pierce the battery with a sharp object such as a needle, screw drivers.
Don't heat partial area of the battery with heated objects such as soldering iron.
Don't hit with heavy objects such as a hammer, weight.
Don't step on the battery and throw or drop the battery on the hard floor to avoid mechanical shock.
Don't disassemble the battery or modify the battery design including electric circuit